材质为有生物相容性的聚氨酯和有机硅,可有效提高通畅度,减少植入过程中对血管内膜的损伤。插管尖端独特的玻璃珠设计,可防止插管脱落,同时在血管内构成一个安全的张力,可以在动物活动时和成长过程中提供管路的持续通畅。
Our biocompatible polyurethane and silicone catheters are designed to enhance patency and minimize vessel trauma during implantation. All these catheters have beads accurately positioned from the catheter tip for optimal implantation position within the vessel. Beads are also positioned to provide a secure tension loop to maximize continued patency during movement and growth.
Part #
MJC-01
MJC-02
MJC-05
Animal Size
<25g
25-30g
>25g
Intravascular Tip Length 9 mm
11 mm
11 mm
Intravascular Tip O.D. 1 F
1 F
2.5 F
Total Length
14 CM
14 CM
12 CM
Connects to Needle
25 ga
25 ga
23 ga
Material
Polyurethane
Polyurethane
Silicone
Beads
2
2
2
Biocompatible polyurethane construction to minimize vessel trauma and increase patency.
Part #
MFV-02
Animal Size
<25g
Intravascular Tip Length 20 mm
Intravascular Tip O.D. 1 F
Total Length
17 CM
Connects to Needle
25 ga
Material
Polyurethane
Beads
2
Our biocompatible catheters for the carotid artery of the mouse are designed for accurate placement to maximize patency. They are sized to fit into small mouse vessels, with suture beads located for optimal positioning. These catheters may be used for blood pressure measurement or infusion.
Part #
MAC-2B
MAC-05
Animal Size
<25g
>25g
Intravascular Tip Length 10 mm
30 mm
Intravascular Tip O.D. 1 F
1 F
Total Length
15 CM
12 CM
Connects to Needle
25 ga
25 ga
Material
Polyurethane
Polyurethane
Beads
2
3
The SAI tail vein access system consists of a very small catheter and stylet that easily inserts into the tail vein of a restrained rodent. The size allows for quick, mistake-free access to the tail vein and once inserted, the flexibility keeps vessel trauma to a minimum. Unlike sharp, stiff needles this catheter moves freely up the vein to ensure the dose goes into the bloodstream, not into the surrounding tissue or back out through the insertion site. It bends naturally with the tail, reducing injury and allowing for continuous infusion or repeated bolus dosing with less chance of ‘losing’ the tail. These catheters are often used for MRI, PET and CT applications and can easily be modified to eliminate all metallic components.
Part #
MTV-01
MTV-02
MTV-02S
MTV-03
Animal Size
All Mice & Rats
All Mice & Rats
All Mice & Rats
All Mice & Rats
Intravascular Tip O.D. 1 F
1 F
1 F
1 F
Stylet
Yes
No
Yes
No
Total Length
28 CM
61 CM
61 CM
91 CM
Connects to Needle
23 ga
23 ga
25 ga
23 ga
Material
Polyurethane
Polyurethane
Polyurethane
Polyurethane
Part #
MTV-05
MTV-BMS1
MTV-11
Animal Size
All Mice & Rats
All Mice & Rats
All Mice & Rats
Intravascular Tip O.D. 1 F
1 F
32 ga
Stylet
No
Yes
No
Total Length
162 CM
14 CM
28 CM
Connects to Needle
23 ga
25 ga
25 ga
Material
Polyurethane
Polyurethane
Polyurethane